Use of Intra-Aortic Balloon Pump (IABP) in Patient with Ventricular Septal Rupture
Abstract
Intra-Aortic Balloon Pump (IABP) can be used among patients with Acute Coronary Syndrome (ACS) who experience Ventricular Septal Rupture (VSR) as a form of mechanical support for hemodynamics that has worsened due to cardiogenic shock. As for the cases reported, a 61-year-old male patient with ACS STEMI Infero-Anterior Extensive Killip 4 and VSR experienced chest pain accompanied by shortness of breath. Auscultatory examination found a heart murmur on 3/6 without thrills. The patient had received drugs to improve hemodynamics and was reported to have used an IABP machine. IABP uses semi-auto mode, 1:1 frequency with maximum augmentation. The patient's condition worsened, and he lost consciousness. The patient then had an endotracheal tube connected to a ventilator.
Keywords: IABP, Intra-aortic-counterpulsation, ventricular septal rupture.
Full Text:
PDFReferences
Antman, E. M., Anbe, D. T., Armstrong, P. W., Bates, E. R., Green, L. A., Hand, M., Hochman, J. S., Krumholz, H. M., Kushner, F. G., Lamas, G. A., Mullany, C. J., Ornato, J. P., Pearle, D. L., Sloan, M. A., & Smith, S. C. (2004). ACC/AHA guidelines for the management of patients with ST-elevation myocardial infarction - Executive summary: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing committee to revise the 199. In Circulation (Vol.
, Issue 5). https://doi.org/10.1161/01.CIR.0000134791.68010.FA
Bonios, M. J., Pierrakos, C. N., Argiriou, M., Dalianis, A., Terrovitis, J. V., Dolou, P., Drakos, S. G., Koudoumas, D., Charitos, C. E., & Anastasiou-Nana, M. I. (2010). Increase in coronary blood flow by intra-aortic balloon counterpulsation in a porcine model of myocardial reperfusion. International Journal of Cardiology, 138(3), 253–260. https://doi.org/10.1016/j.ijcard.2008.08.015
Crenshaw, B. S., Granger, C. B., Birnbaum, Y., Pieper, K. S., Morris, D. C., Kleiman, N. S., Vahanian, A., Califf, R. M., & Topol, E. J. (2000). Patients With Ventricular Septal Defect Complicating Acute Myocardial Infarction.
De Silva, K., Lumley, M., Kailey, B., Alastruey, J., Guilcher, A., Asrress, K. N., Plein, S., Marber, M., Redwood, S., & Perera, D. (2014). Coronary and microvascular physiology during intra-aortic balloon counterpulsation. JACC: Cardiovascular Interventions, 7(6),
–640. https://doi.org/10.1016/j.jcin.2013.11.023
González, L. S., & Chaney, M. A. (2020). Intraaortic balloon pump counterpulsation, part I: History, technical aspects, physiologic effects, contraindications, medical applications/outcomes. Anesthesia and Analgesia, 131(3), 776–791. https://doi.org/10.1213/ANE.0000000000004954
Kantrowitz, A., Tjønneland, S., Freed, P. S., Phillips, S. J., Butner, A. N., & Sherman, J. L. (1968). Initial Clinical Experience With Intraaortic Balloon Pumping in Cardiogenic Shock. JAMA: The Journal of the American Medical Association, 203(2), 113–118. https://doi.org/10.1001/jama.1968.03140020041011
Kettner, J., Sramko, M., Holek, M., Pirk, J., & Kautzner, J. (2013). Utility of intra-aortic balloon pump support for ventricular septal rupture and acute mitral regurgitation complicating acute myocardial infarction. American Journal of Cardiology, 112(11),
–1713. https://doi.org/10.1016/j.amjcard.2013.07.035
Krishna, M., & Zacharowski, K. (2009). Principles of intra-aortic balloon pump counterpulsation. Continuing Education in Anaesthesia, Critical Care and Pain, 9(1),
–28. https://doi.org/10.1093/bjaceaccp/mkn051
Limbert, & Amiri. (2019). Intra-Aortic Balloon Pump for Patients with Cardiac Conditions:
An Update on Available Techniques and Clinical Applications. Reports, 2(3). https://doi.org/10.3390/reports2030019
Moreyra, A. E., Huang, M. S., Wilson, A. C., Deng, Y., Cosgrove, N. M., & Kostis, J. B. (2010). Trends in incidence and mortality rates of ventricular septal rupture during acute myocardial infarction. American Journal of Cardiology, 106(8), 1095–1100. https://doi.org/10.1016/j.amjcard.2010.06.013
Oktaviono, Y. H. (2016). Case Report: USE OF INTRA-AORTIC BALLOON PUMP
(IABP) IN HIGH-RISK PERCUTANEOUS CORONARY INTERVENTION
PROCEDURE. Folia Medica Indonesiana, 51(3), 196. https://doi.org/10.20473/fmi.v51i3.2839
Prondzinsky, R., Knüpfer, A., Loppnow, H., & Werdan, K. (2003). Cardiogenic shock in acute myocardial infarction. Intensiv- Und Notfallbehandlung, 28(2), 100–112.
https://doi.org/10.5414/ibp28100
Ronco, D., Matteucci, M., Ravaux, J. M., Marra, S., Torchio, F., Corazzari, C., Massimi, G., Beghi, C., Maessen, J., & Lorusso, R. (2021). Mechanical Circulatory Support as a Bridge to Definitive Treatment in Post-Infarction Ventricular Septal Rupture. JACC:
Cardiovascular Interventions, 14(10), 1053–1066.
https://doi.org/10.1016/j.jcin.2021.02.046
Siegel. (2002). Ventricular Septal Rupture After Acute Myocardial Infarction. English Journal, 347(18), 1426–1432.
Webb, C. A. J., Weyker, P. D., & Flynn, B. C. (2015). Management of intra-aortic balloon pumps. Seminars in Cardiothoracic and Vascular Anesthesia, 19(2), 106–121.
https://doi.org/10.1177/1089253214555026
DOI: https://doi.org/10.24198/mkk.v6i2.48187
Refbacks
- There are currently no refbacks.
JURNAL INI TERINDEKS DI:









Penerbit :
Fakultas Keperawatan, Universitas Padjadjaran
Jalan Raya Bandung-Sumedang Km. 21 Jatinangor, Sumedang, Indonesia 45363
WA: 085317736810
Tlp. 022-7795596
Email: info.mkk.keperawatan@unpad.ac.id
Email: novita.trivita@gmail.com
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License