The accuration of parallel radiograph technique in measurement of alveolar crest resorption on removable orthodontic treatment

Aisa Nirmala Setyani, Belly Sam, Elih Syiarudin

Abstract


Introduction: The parallel radiograph technique produce the accurate measurement so that it can be used to detect the small changing in the hard tissue. In the orthodontic treatment, the force which is given when the activation make the resorption of alveolar crest happen. The purpose of this study is to obtain data of the photo using radiograph periapikal parallel technique and the resorption of alveolar crest in orthodontic treatment during 3 weeks after the first activation. Methods: This quantitative descriptive study used the accidental sampling methode. The data was collected by using parallel radiograpy photo when the first aktivation of coil component in the removable orthodontic patient and 3 weeks after it. Then it was digitilized using the camera and proceeded by Easydent program. After that the tooth lenght of the first and second photos was counted. While to measure the a lveolar crest used the matematic proyection. Results: The result showed p>0,05 which meaned there was no significant differences of the tooth lenght between the first and second photos. The resorption of alveolar crest in this removable orthodontic treatment after the force was given during 3 weeks, was 0, 69899 mm. Conclusion: The parallel radiography technique which is used in this study could be used in the measurement of such condition with reccurent time and the accurate result, and the resorption of the alveolar crest in the insisive central mandibule effected by removable orthodontic treatment was in normal range.


Keywords


Accuracy – alveolar bone resorption – coil – parallel radiograph –removable orthodontic

Full Text:

PDF

References


White SC, Goaz PW, Oral Radiology Principle and Interpretation. St. Louis Mosby Inc. 1994

Kunzel AD, Scherkowski R, Willers, Becker J. Visually detectable resolution of intraoral dental films. Dent Rad J. 2003;32(1):385-389.

Vasconcelos KF, Evangelista KM, Rodrigues CD, Estrela C, de Sousa TO, Silva MAG. Detection of periodontal bone loss using cone beam CT and intraoral. Dent Rad J. 2012;41(1):64-69

Lofthag H, Lindh R, Petersson A. Radiographic assessment of the marginal bone level after implant treatment: a comparison of periapical and Scanora detailed narrow beam radiography. Dentomax fac Rad J. 32(1):97-103.

Formoso NFB. Rilo MJ, Mora IM, Silva, Santana U. A paralleling technique modification to determine the bone crest level around dental implants. Dentomax fac Rad J. 2011;40(1) 385-389.

Frommer HH, Savage JJS. Radiology for The Dental Professional ed 8. Missouri : Mosby, Inc. 2005.

Isaacson KG, Muir JD, Reed RT. Removable Orthodontic Appliances. India Elsevier. 2002. 1-7, 11-13, 15-17.

Lau PY, Wong RW. Risks and complications in orthodontic treatment. Hongkong Dental Journal, 2006;3(1)15-22. Available online at http://ncbi.nlm.nih.gov (diakses 16 November 2011).

Lindauer SJ. The basics of orthodontic mechanics. in Seminars in Orthodontics, 2001;7(1)2-15

Pierro VSS, de Souza IPR, Luiz RR, Barcelos R, Moraes RS. Reliability of two methods for measurement of alveolar bone level in children. Dent Rad J. 2008;37(1)34-39.

Salonen LWE,Frithiof L, Wouters FR, Hellden LB. Marginal alveolar bone height in an adult swedish population. A radiographic cross-sectional epidemiologic study. J Clin Period. 1991;18(1)223-232.

Yunus B. Pengukuran tulang rahang dengan ct-scan sebagai faktor koreksi terhadap radiografi gigi konvensional untuk pemasangan implan gigi. JST Kesehatan. April 2011;1(1):10–18.

Moradi JF. Poorsafar M. Khoshhal. A comparison of two radiographic technique to determine the distance between alveolar bone crest and cementoenamel junction in patient with chronic periodontitis. DJH. 2010;1(2)1-7

Woo BM, Zee KY, Chan FH, Corbet EF. In vitro calibration and validation of a digital subtraction radiography system using scanned images. J Clin Periodontol 2003;30:114-8.

Khojastehpaur LH, Khosropanah, MJ, Kharazifard. The effect of bite registration on the reproduc-ibility of parallel periapical radiographs obtained with two month intervals. J Dent, Tehran Uni-versity of Medical Sciences. 2006;3(2).




DOI: https://doi.org/10.24198/pjd.vol26no1.26752

Refbacks

  • There are currently no refbacks.


Visitor Stat

Creative Commons License
Padjadjaran Journal of Dentistry is licensed under Creative Commons Attribution 4.0 International License