Differences level of hybrid resin composite’s hardness based on post-irradiation time with photoactivated light emitting diode

Esther Bianca, Milly Armilia Andang, Endang Sukartini

Abstract


Introduction: Adequate surface hardness of the resin composites is important to obtain optimum clinical performance of the restoratives in stress dental bearing areas. For light-activated resin composites, polymerization begins when curing light initiates polymerization and continues after the curing light goes off. The degree of conversion and hardness of resin composite is also affected by post-irradiation time. The objective of this study was to evaluate the difference of the hardness hybrid resin composite based on post-irradiation time at 10 minutes, 24 hours, and 7 days with photoactivated light-emitting diode (LED) to obtain the optimum hardness. Methods: This study was using a true experimental research method. Thirty samples of hybrid resin composites, disk-shaped of 6 mm in diameter and 2 mm in depth were polymerized by LED LCU at 800mW/cm2 for 20 seconds. The hardness of the resin composite was measured by Vickers Hardness Tester. The result was analyzed statistically with ANOVA. Results: There was a significant difference level of hardness among the three groups. Hardness mean value for post-irradiation time at 10 minutes was 56,4 VHN, for post-irradiation time at 24 hours was 65,8 VHN, and for post-irradiation time at 7 days was 60,0 VHN. Conclusion: There were differences level of hybrid resin composite’s hardness based on the post-irradiation time at 10 minutes, 24 hours, and 7 days with photoactivated LED and the optimum hardness of post-irradiation time at 24 hours.


Keywords


Hardness, hybrid composite, post-irradiation time, LED.

Full Text:

PDF

References


Roberson TM, Heymann HO, Swift EJ. Sturdevant’s Art and Science of Operative Dentistry. 5th ed. India: Mosby; 2006.

Bona AD, Rosa V, Cecchetti D. Influence of shade and irradiation time on the hardness of composite resins. Braz Dent J. 2007; 18(3):231-234.

Garcia AH, Lozano MAM, Vila JC, Escribano AB, Gaive PF. Composite resins. A review of the materials and clinical indications. Med Oral Patol Oral Cir Bucal. 2006;11:E215-20.

Small BW. Direct resin composites for 2002 and beyond. Gen Dent 2002;50(1):30-3.

Aguiar FH, Lazzari CR, Lima DA, Ambrosano GM, Lovadino JR. Effect of light curing distance and resin shade on microhardness of a hybrid resin composite. Braz Oral Res. 2005 Oct-Dec;19(4):302-6.

Kawai K, Leinfelder KF. Effect of surface-penetration sealant on composite wear. Dent Mater. 1993;9:108-13.

Anusavice K. Phillips Science of Dental Material. 11th ed. St. Louis: W.B.Saunders Co; 2003.

Marghalani HY. Post-irradiation vickers microhardness development of novel resin vomposites. Material Research. 2010; 13(1):81-7.

Dhuru VB. Contemporary Dental Materials. New delhi: Oxford University Press; 2004.

Mohamad Da, Young RJ, Mann AB, Watts DC. Post-polymerization of dental resin composite evaluated with nanoindentation and micro-Raman spectroscopy. Archives of Orofacial Sciences 2007:2:26-31

Chinelatti MA, Chimello DT, Ramos RP, Palma RG. Evaluation of the surface hardness of composite resins before and after polishing at different times. J Apply Oral Sci 2006; 14(3):188-92.

Craig RG, Powers JM. Restorative Dental Materials. 12th ed. St.Louis: Mosby; 2006.

Albers HF. Tooth-Colored Restoratives Principles and Techniques. 9th Ed. London: BC Decker Inc Hamilton; 2002.

Ciccone-Nogueira JC, Borsatto MC, de Souza-Zaron WC, Ramos RP, Palma-Dibb RG. Microhardness of composite resins at different depths varying the post-irradiation time. J Apply Oral Sci. 2007;15(4).

Correr AB, Sinhoreti MAC, Correr SL, Tango RN, Consani S, Schneider LFJ. Effect of exposure time vs irradiance on knoop hardness of dental composite. Material Research. 2006;9(3):275-80.

Rahiotis C, Patsouri K, Silikas N, Kakaboura A. Curing efficiency of high-intensity light-emitting diode (LED) devices. Journal of Oral Science. 2010; 52(2):187-195.

Emami ND, Soderholm KJ. Young’s modulus and degree of conversion of different combination of light-cure dental-resins. Open Dent J. 2009;3:202-7.

Nagas IC, Ergun G, Vallittu PK, Lassila LVJ. Influence of polymerization mode on degree of conversion and micropush-out bond strength of resin core systems using different adhesive systems. Dent Mat J 2008;27(3):376-85.

Martos J, Osinaga PWR, de Oliveira E, de Castro LAS. Hydrolitic degradation of composite resins: effect on the microhardness. Material Research. 2003;16(4):599-604.

Berger SB, Palialol ARM, Cavalli V, Giannini M. Characterization of water sorption and filler particles of light-cured composite resins. Braz Dent J. 2009;20(4):314-318.




DOI: https://doi.org/10.24198/pjd.vol24no2.26825

Refbacks

  • There are currently no refbacks.


Visitor Stat

Creative Commons License
Padjadjaran Journal of Dentistry is licensed under Creative Commons Attribution 4.0 International License