Nanopartikel Emas, Solusi Mutakhir Deteksi Kolesterol Terakurat
Abstrak
Konsentrasi normal kolesterol bebas dalam serum manusia di bawah 5,2 mM, tetapi apabila berlebih dapat mengakibatkan gangguan pembuluh jantung, stroke dan yang paling fatal dapat mengakibatkan kematian. Deteksi kolesterol dengan karbon berukuran nano (IDE) yang dilapisi nanopartikel emas (AuNPs), mampu memberikan respon yang cepat, sensitif dan selektif. Dalam artikel mini review ini dibahas terkait alat deteksi kolesterol nanopartikel emas yang dilakukan dengan menggunakan teknik elektrokimia didasarkan pada pengukuran arus.
Keyword : nanopartikel, emas, kolesterlol, deteksi
Teks Lengkap:
PDFReferensi
Ahn, K.-W.; Sampson, N.S. Cholesterol oxidase senses subtle changes in lipid bilayer structure. Biochemistry 2004, 43, 827–836 American Heart Association. 2018. Cholesterol. Tersedia secara online di http://www.heart.org/HEARTORG/Conditions/Cholesterol/AboutCholesterol/About-Cholesterol_UCM_001220_Article.jsp#.WyG0QfmFPIU . [diakses pada tanggal 14 Juni 2018] [2] B.R. Eggins.2002 .Chemical Sensors and Biosensors,John Wiley. Chichester, . p.273.
Batra, N.; Tomar, M.; Gupta, V. ZnO-CuO composite matrix based reagentless biosensor for detection of total cholesterol. Biosens. Bioelectron. 2015, 67, 263–271.
D.L. Wise.1991. Bioinstrumentation and Biosensors. Marcel Dekker Inc. New York. p.824.
Derks, H.J.G.M.; van Heiningen, A.; Koedam, H.C. Gas-chromatographic determination of cholesterol in serum: candidate reference method. Clin. Chem. 1985, 31, 691–694.
Giri, A.K.; Charan, C.; Saha, A.; Shahi, V.K.; Panda, A.B. An amperometric cholesterol biosensor with excellent sensitivity and limit of detection based on an enzyme-immobilized microtubularZnO@ZnSheterostructure. J. Mater. Chem. A 2014, 2, 16997–17004
Manjunatha, R.; Suresh, G.S.; Melo, J.S.; D’Souza, S.F.; Venkatesha, T.V. An amperometric bienzymatic cholesterol biosensor based on functionalized graphene modified electrode and its electrocatalytic activity towards total cholesterol determination. Talanta 2012, 99, 302–309.
Sharma, D.et al. 2017. Development of a Sensitive Electrochemical Enzymatic Reaction-Based Cholesterol Biosensor Using Nano-Sized Carbon Interdigitated Electrodes Decorated with Gold Nanoparticles. MDPI AG. Switzerland. 17(9), 2128
Qureshi, R.N.; Kaal, E.; Janssen, H.-G.; Schoenmakers, P.J.; Kok, W.T. Determination of cholesterol and triglycerides in serum lipoproteins using flow field-flow fractionation coupled to gas chromatography-mass spectrometry. Anal. Chim. Acta2011, 706, 361–366.
Razzazi-Fazeli, E.; Kleineisen, S.; Luf, W. Determination of cholesterol oxides in processed food using high performance liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization. J. Chromatogr. 2000, 896, 321–334.
Nakajima, M.; Yamato, S.; Wakabayashi, H.; Shimada, K. High-performance liquid chromatographic determination of cholesterol and cholestanol in human serum by precolumnderivatization with 2-[2-(isocyanate)ethyl]-3-methyl-1,4-naphthoquinone combined with platinum catalyst reduction and electrochemical detection. Biol. Pharm. Bull. 1995, 18, 1762–1764.
Sharma, A.; Artiss, J.D.; Zak, B. A method for the sequential colorimetric determination of serum triglycerides and cholesterol. Clin. Biochem. 1987, 20, 167–172.
Wang, C.; Tan, X.; Chen, S.; Yuan, R.; Hu, F.; Yuan, D.; Xiang, Y. Highly-sensitive cholesterol biosensor based on platinum-gold hybrid functionalized ZnOnanorods. Talanta 2012, 94, 263–270
Zhu, L.; Xu, L.; Tan, L.; Tan, H.; Yang, S.; Yao, S. Direct electrochemistry of cholesterol oxidase immobilized on gold nanoparticles-decorated multiwalled carbon nanotubes and cholesterol sensing. Talanta 2013, 106, 192–199.
Feng, B.; Liu, Y.-N. A disposable cholesterol enzyme biosensor based on ferrocene-capped gold nanoparticle modified screen-printed carbon electrode. Int. J. Electrochem. Sci. 2015, 10, 4770–4778.
Malhotra, B.D.; Kaushik, A. Metal oxide-chitosan based nanocomposite for cholesterol biosensor. Thin Solid Films 2009, 518, 614–620.
Vidal, J.-C.; Espuelas, J.; Garcia-Ruiz, E.; Castillo, J.-R. Amperometric cholesterol biosensors based on the electropolymerization of pyrrole and the electrocatalytic effect of Prussian-Blue layers helped with self-assembled monolayers. Talanta 2004, 64, 655–664.
Manjunatha, R.; Nagaraju, D.H.; Suresh, G.S.; Melo, J.S.; D’Souza, S.F.; Venkatesha, T.V. Direct electrochemistry of cholesterol oxidase on MWCNTs. J. Electroanal. Chem. 2011, 651, 24–29.
Sharma, R.; Sinha, R.K.; Agrawal, V.V. Mediator-free total cholesterol estimation using a bi-enzyme functionalized nanostructured gold electrode. RSC Adv. 2015, 5, 41786–41794.
Guo, M.; Chen, J.; Li, J.; Nie, L.; Yao, S. Carbon nanotubes-based amperometric cholesterol biosensor fabricated through layer-by-layer technique. Electroanalysis2004, 16, 1992–1998.
Li, J.; Peng, T.; Peng, Y. A cholesterol biosensor based on entrapment of cholesterol oxidase in a silicic sol-gel matrix at a prussian blue modified electrode. Electroanalysis 2003, 15, 1031–1037.
Liu, X.; Nan, Z.; Qiu, Y.; Zheng, L.; Lu, X. Hydrophobic ionic liquid immobilizing cholesterol oxidase on the electrodeposited Prussian blue on glassy carbon electrode for detection of cholesterol. Electrochim. Acta 2013, 90, 203–309
Xu, L.; Zhang, M.; Hou, Y.; Huang, W.; Yao, C.; Wu, Q. An Au nanocomposite based biosensor for determination of cholesterol. Anal. Methods 2015, 7, 3480–3485.
Safavi, A.; Farjami, F. Electrodeposition of gold-platinum alloy nanoparticles on ionic liquid-chitosan composite film and its application in fabricating an amperometric cholesterol biosensor. Biosens. Bioelectron. 2011, 26, 2547–2552.
Ji, J.; Zhou, Z.; Zhao, X.; Sun, J.; Sun, X. Electrochemical sensor based on molecularly imprinted film at Au nanoparticles-carbon nanotubes modified electrode for determination of cholesterol. Biosens. Bioelectron. 2015, 66, 590–595.
Bonomi, R.; Cazzolaro, A.; Sansone, A.; Scrimin, P.; Prins, L.J. Detection of enzyme activity through catalytic signal amplification with functionalized gold nanoparticles. Angew. Chem. Int. Ed. 2011, 50, 2307–2312.
Xiao, Y.; Patolsky, F.; Katz, E.; Hainfeld, J.F.; Willner, I. “Plugging into Enzymes”: Nanowiring of redox enzymes by a gold nanoparticle. Science 2003, 299, 1877–1881.
Hutter, E.; Maysinger, D. Gold-nanoparticle-based biosensors for detection of enzyme activity. Trends Pharmacol. Sci. 2013, 34, 497–507.
Marhaendrajaya, Indras., Eko Hidayanto., Zaenal Arifin dan Heri Sutanto. Desain dan realisasi alat pengukurkan dengan kolesterol dalam darah non-invasive. Youngster Physics Journal.2017 6(3) : 290-295.
Refbacks
- Saat ini tidak ada refbacks.